Clean regularly & change annually. Filters up to 150 GPD (gallons per day) of ultra-pure, low PPM water
Features:
- 96% – 99% PPM Rejection
- Membrane Type: Thin Film Composite
- Maximum Operating Temperature: 113°F (45°C)
- Maximum Operating Pressure: 100 PSI
- Maximum Feed Flow Rate: 2 GPM
- Maximum Feed Water Turbidity: 1 NTU
- Maximum Feed Sit Density Index (SDI): 5 SDI
- Chlorine Tolerance: <0 PPM
- Dimensions (H x W x D): 12" x 2" x 2"
- Weight: .5 lbs
- Tariff: 8421990040
THERE ARE TWO INDICATIONS AS TO WHEN TO CHANGE YOUR MEMBRANES
- Test the RO and source/inlet water to see what percentage of the inlet water’s PPM the 150™ is filtering out (rejection %). You should see approximately 98% of the inlet PPM’s being removed when the membrane is new. If the rejection % falls under an acceptable level (typically 90%) it’s time to change the membrane
- When the flow rate of the product water slows down significantly. This can also happen if your pre-filters are clogged. If you change your pre-filters and the product water still flows slowly then it’s an indication you need a new membrane. When it doubt contact HydroLogic